Class DC-8 Eros Mask Crew Oxygen System Design
Jetaire was awarded a contract by a major cargo airline
to design a Flight Crew Oxygen system for their DC-8
aircraft. The system design incorporated five EROS masks.
A flow and duration analysis was completed to determine
the amount of Oxygen required to support crew activities
at the aircraft’s service ceiling in the event of an
emergency. Complete tubing, hose, wire routing, installation,
testing, and maintenance documentation was developed.